Controller Temperature Reading Jumps
Symptoms
If you notice that your controller’s temperature reading on the display is unstable, fluctuating without any motor input, this may lead to an "Error Code 5" or display the message "Controller Over Temperature."
Note: If your controller’s temperature reading is consistently high but stable, please refer to a different article for assistance: 📄 08PG4 - X1 Pro Gen 4: Error codes
Possible Causes
This issue may be caused by:
- A firmware glitch
- A malfunctioning temperature probe in the motor
Troubleshooting Steps
- Reflash the Firmware: Use the CYC Ride Control app or connect to a PC to reflash the firmware. Follow the instructions in this article: 📄 X1 Pro Gen 4: Firmware
- Replace the motor: If reflashing the firmware does not resolve the issue, you will need to replace the motor.
Warranty Information
If the motor is still within its warranty period and shows no signs of physical alteration (such as cut wires), the necessary components will be replaced under warranty.